![]() Protective Clothing |
|
CHEMICAL PERMEATION / PENETRATION TESTING ASTM F1001 Recommended List of Chemicals Fpr Evaluating Protective Clothing Materials (ASTM F739) Chemical Penetration Testing (ASTM P903) |
||||
| Challenge Chemical |
Average Normalized Breakthrough Time (minutes) |
Average Permeation Rate (ug/cm2/minute) |
Penetration Results |
|
| Acetone | 8 | 0.62 | PASS | |
| Acetonitrile | <4 | 8.7 | PASS | |
| Ammonia | 4 | 4.5 | N/T | |
| 1,3-Butadiene | 8 | 11.9 | N/T | |
| Carbon Disulfide | <4 | <50 | PASS | |
| Chlorine Gas | 6 | 2.3 | N/T | |
| Dichloromethane | 4 | 0.59 | PASS | |
| Diethylamine | 4 | 9.5 | PASS | |
| N,N-Dimethylformamide | 8 | 2.1 | PASS | |
| Ethyl Acetate | 4 | 2.3 | PASS | |
| Ethylene Oxide | <4 | 359 | N/T | |
| n-Hexane | 4 | 6.3 | PASS | |
| Hydrogen Chloride | 30 | >50 | N/T | |
| Methanol | <4 | 2.23 | PASS | |
| Methyl Chloride | 4 | 0.38 | N/T | |
| Nitrobenzene | 4 | 16 | PASS | |
| Sodium Hydroxide | ND | ND | PASS | |
| Sulfuric Acid | ND | ND | PASS | |
| Tetrachloroethylene | 8 | 10 | PASS | |
| Tetrahydrofuran | <4 | <50 | PASS | |
| Toluene | 48 | 25 | PASS | |
|
||||
|
COMPARATIVE COMPOSITE DATA SHEET |
||||
| Property | Method | POSI-WEARTM | Tyvek® Grade 1422A | |
| Weight (oz/yd2) | ASTM D-1910 | 1.71 | 1.15 | |
| Thickness (mils) | ASTM 1777*64 | 10 | 5 | |
| Tensile Strength (lbs.) MD | ASTM D-1682 | 34 | 17 | |
| Tensile Strength (lbs.) CD | Grab | 19 | 18 | |
| Tensile Strength (lbs.in) MD | ASTM D-1682 | 10 | 7 | |
| Tensile Strength (lbs.in) CD | Strip | 6 | 9 | |
| Trapezoid Tear | ASTM D-2263 | >10 | 5 | |
| Trapezoid Tear (lbs.) CD | >7 | 6 | ||
| Bond Strength (lbs.) MD | IST 110*2*82 | Min. 1.0 | Not Applicable | |
| Bond Strength (lbs.) CD | Min. 1.0 | Not Applicable | ||
| Hydrostatic Head (cms) | >100 | <75 | ||
| Moisture Vapor Trans. | ASTM F-1249 | Not Applicable | LOW | |
| Resistance to Penetration by Liquids (2 psi) | ASTM ES-21 | PASS | Not Applicable | |
|
||||
|
|
|
| Click here for home | Click here for order page |